Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 74
Filter
1.
Braz. j. oral sci ; 23: e241938, 2024. ilus
Article in English | LILACS, BBO | ID: biblio-1532506

ABSTRACT

Aim: To evaluate changes in the surface roughness and morphology of a nanofilled composite following toothbrushing with a whitening (WT) or regular toothpaste (RT), alone or combined with 35% hydrogen peroxide bleaching (HP). Methods: Seventy disc-shaped nanofilled composite (Filtek Z350XT) specimens were randomly divided into groups (n=10): WT, RT, TB (without toothpaste ­ control) or the combinations WT/ HP, RT/HP, TB/HP and HP. All groups underwent toothbrushing simulation (60,000 cycles) and bleaching treatment (4 sessions). Mean surface roughness (Ra, µm) was measured before (T0) and after treatments (TB). Surface morphology was assessed by scanning electron microscopy (SEM) at TB. Mean Ra was analyzed using general mixed models and multiple comparisons by the Tukey-Kramer test (α=5%). Results: HP caused no surface roughness changes on the nanofilled composite after treatment (p>0.05). RT toothbrushing, combined or not with HP, increased the surface roughness (p<0.05). WT and WT/ HP protocols had no effect on the surface roughness of the composite (p>0.05). The nanofilled composite submitted to RT toothbrushing combined with HP (RT/HP) presented substantial surface alterations under SEM, showing deep depressions and round-shaped defects. Toothbrushing with RT combined with the bleaching agent increased exposure of the inorganic fillers. Conclusion: WT toothbrushing, regardless of HP combination, or the single HP protocol had no effect on the surface roughness of the nanofilled composite. However, RT combined with HP negatively affected surface roughness and presented the most noticeable surface changes among groups


Subject(s)
Tooth Bleaching , Toothpastes , Microscopy, Electron, Scanning , Composite Resins , Hydrogen Peroxide
2.
Braz. j. oral sci ; 21: e224013, jan.-dez. 2022. ilus
Article in English | BBO, LILACS | ID: biblio-1354702

ABSTRACT

Aim: The aim of the study was to evaluate the cleaning of mandibular incisors with WaveOne Gold® (WO) under different preparation techniques. Methods: A total of 210 human mandibular incisors were selected and divided into seven groups (n = 30), prepared by WO single-files (Small 20/.07 ­ WOS; Primary 25/.07 ­ WOP; Medium 35/.06 ­ WOM; or Large 45/.05 - WOL) and sequential-file techniques (WOS to WOP; WOS to WOM; and WOS to WOL). Further subdivision was made according to irrigation protocol: control group (manual irrigation - CON), E1 Irrisonic® - EIR, and EDDY® - EDD. Debris removal and the smear layer were evaluated by scanning electron microscopy. Data were analyzed by using Spearman's correlation test. The significance level was set at 5%. Results: For debris and smear layer removal, WOS and WOP, EIR differed from CON and EDD (p <0.05). Conclusion: Regardless of the instrumentation used, the agitation of the irrigant solution provided better cleanability. These findings reinforce the need for agitation techniques as adjuvants in cleaning root canal systems in mandibular incisors


Subject(s)
Root Canal Irrigants , Microscopy, Electron, Scanning , Root Canal Preparation , Endodontics
3.
Braz. oral res. (Online) ; 36: e115, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1403967

ABSTRACT

Abstract This study evaluate shaping ability of heat-treated NiTi-alloy instruments associated with different final irrigation protocols in flattened root canals. Thirty human mandibular incisors with flattened root canals were divided into 5 groups (n = 10): (XP) Original Protocol XP-endo Shaper; (XP-WT) Original Protocol XP-endo Shaper with working time variation; (XP-K) XP-endo Shaper with kinematics variation; (XP-WTK) XP-endo Shaper with kinematics and working time variations; (Hyflex) Hyflex CM. For the variation in working time protocols the same sample of the XP-endo Shaper groups with and without kinematic variation were used. To evaluate final irrigation protocols, groups 1, 3 and 5 were submitted to 3 protocols: (NI) No irrigation (n = 2); (CI) conventional irrigation (n = 4), and (EndoVac) irrigation (n = 4). The samples were scanned by microcomputed tomography and prepared for scanning electron microscopy evaluation. Quantitative data were evaluated using the parametric ANOVA test, with statistical significance level set at 5%, and qualitative data obtained were compared to establish the agreement between examiners through the Kappa test. It was observed that in the analysis of XP-endo Shaper protocols, the additional working time did not cause difference in any of parameters evaluated (p > 0.05) in relation to time recommended by manufacturer. Compared to Hyflex, XP-K showed highest mean volume increase (p < 0.05) and lowest percentage of untouched walls (p < 0.05). In the qualitative evaluation, final irrigation protocol with EndoVac provided the best cleaning results when associated with XP-K and with Hyflex. Thus, supplementary techniques are effective tools to enhance cleaning and to promote higher touch of walls during root canal preparation.

4.
Rev. Esc. Enferm. USP ; 56: e20210552, 2022. graf
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1365410

ABSTRACT

ABSTRACT Objective: To analyze the microbiological and microstructural part of indwelling urinary catheters and their association with urinary tract infection prevention. Method: This is a cross-sectional study, from June to December 2020, in which 42 indwelling urinary catheter tips and sterile urine samples were collected for analysis of crystals in optical microscopy and biofilms in scanning electron microscopy. Culture analysis and specification of the type of bacteria were performed. Results: It was found that 35.71% of the samples had mature biofilm adhered to the catheter tip. Biofilms of Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium and Enterobacter cloacae stood out. The presence of magnesium-ammonium-phosphate crystal was associated with the presence of urinary tract infection and with Proteus mirabilis. There was a significant association (p = 0.001) between the use of prophylactic antibiotics versus urine culture >105 CFU/mL. Conclusion: The analyzes contributed to clinical practice, as it reinforces the development of effective and monitored strategies on cultures and urinary tract infection prevention associated with indwelling urinary catheters.


RESUMEN Objetivo: Analizar la parte microbiológica y microestructural de los catéteres urinarios permanentes y su asociación con la prevención de la infección del tracto urinario. Método: Transversal, de junio a diciembre de 2020, en el que se recolectaron 42 puntas de sonda urinaria permanente y muestras de orina estéril para análisis de cristales en microscopía óptica y biopelículas en microscopía electrónica de barrido. Se realizaron análisis de cultivo y especificación del tipo de bacteria. Resultados: Se encontró que el 35,71% de las muestras presentaban biopelícula madura adherida a la punta del catéter. Se destacaron las biopelículas de Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium y Enterobacter cloacae. La presencia de cristales de fosfato de magnesio-amonio se asoció con la presencia de infección del tracto urinario y con Proteus mirabilis. Hubo una asociación significativa (p = 0,001) entre el uso de antibióticos profilácticos versus urocultivo >105 UFC/mL. Conclusión: Los análisis contribuyeron a la práctica clínica, ya que refuerzan el desarrollo de estrategias efectivas y monitoreadas sobre cultivos y prevención de la infección del tracto urinario asociada a los catéteres urinarios permanentes.


RESUMO Objetivo: Analisar a parte microbiológica e microestrutural dos cateteres vesicais de demora e sua associação com a prevenção de infecção do trato urinário. Método: Transversal, entre junho e dezembro de 2020, em que foram coletadas 42 pontas cateteres vesicais de demora e amostras de urina estéril para análise de cristais em microscopia óptica e de biofilmes em microscopia eletrônica de varredura. Fez-se analise de cultura e especificação do tipo de bactérias. Resultados: Verificou-se que 35,71% das amostras apresentaram o biofilme maduro aderido à ponta do cateter. Destacaram-se biofilmes de Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium e Enterobacter cloacae. A presença do cristal magnésio-amônio-fosfato foi associada à presença de infecção do trato urinário e ao Proteus mirabilis. Verificou-se associação significativa (p = 0,001) entre o uso de antibiótico profilático versus a urocultura >105 UFC/mL. Conclusão: As análises contribuíram para a prática clínica, pois reforçam a elaboração de estratégias efetivas e monitoradas sobre culturas e prevenção de infecção do trato urinário associada ao cateter vesical de demora.


Subject(s)
Urinary Tract Infections , Urinary Catheters , Microscopy, Electron, Scanning , Public Health , Public Health Surveillance
5.
Braz. j. oral sci ; 20: e214873, jan.-dez. 2021. ilus
Article in English | BBO, LILACS | ID: biblio-1254742

ABSTRACT

Aim: To compare the marginal fit of lithium disilicate CAD/CAM crowns and heat-pressed crowns fabricated using milled wax patterns, and evaluate its effect on stress distribution in implantsupported rehabilitation. Methods: A CAD model of a mandibular first molar was designed, and 16 lithium disilicate crowns (8/group) were obtained. The crown-prosthetic abutment set was evaluated in a scanning electron microscopy. The mean misfit for each group was recorded and evaluated using Student's t-test. For in silico analysis, a virtual cement thickness was designed for the two misfit values found previously, and the CAD model was assembled on an implant-abutment set. A load of 100 N was applied at 30° on the central fossa, and the equivalent stress was calculated for the crown, titanium components, bone, and resin cement layer. Results: The CAD/CAM group presented a significantly (p=0.0068) higher misfit (64.99±18.73 µm) than the heat-pressed group (37.64±15.66 µm). In silico results showed that the heat-pressed group presented a decrease in stress concentration of 61% in the crown and 21% in the cement. In addition, a decrease of 14.5% and an increase of 7.8% in the stress for the prosthetic abutment and implant, respectively, was recorded. For the cortical and cancellous bone, a slight increase in stress occurred with an increase in the cement layer thickness of 5.9% and 5.7%, respectively. Conclusion: The milling of wax patterns for subsequent inclusion and obtaining heat-pressed crowns is an option to obtain restorations with an excellent marginal fit and better stress distribution throughout the implant-abutment set


Subject(s)
Microscopy, Electron, Scanning , Computer-Aided Design , Dental Marginal Adaptation , Dental Prosthesis, Implant-Supported , Finite Element Analysis , Dental Materials
6.
An. bras. dermatol ; 96(3): 328-331, May-June 2021. graf
Article in English | LILACS | ID: biblio-1285053

ABSTRACT

Abstract Cutis rhomboidalis nuchae was assessed in a 65-year-old patient. Optical microscopy showed basophilic agglomerations in the reticular dermis with decreased elastic fibers. Trans- mission electron microscopy showed elongated, curved and fragmented structures, and in their interior the presence of electron-dense lumps was reduced and irregular, similar to modified elastic fibers, whereas the collagen fibers had a normal aspect. Scanning electron microscopy showed deposits between the bundles of collagen, resembling pebbles or stones. These findings demonstrate that, at one stage of the disease, the collagen remains normal and the alterations are seen in the elastic tissue.


Subject(s)
Humans , Aged , Skin Diseases , Microscopy, Electron, Scanning , Dermis , Microscopy, Electron, Transmission , Elastic Tissue
7.
Article in English | LILACS, BBO | ID: biblio-1135540

ABSTRACT

Abstract Objective: To assess the antibacterial and smear layer removal ability of Trigonella foenum, Syzygium cumini, Terminalia chebula seed extracts against E. faecalis dentinal biofilm. Material and Methods: Agar well diffusion, micro broth dilution assay and time-kill curve assay were performed to determine the antibacterial activity. The ability of the herbal extracts to remove the smear layer on the root canal surface was assessed by scanning electron microscopy. Results: Antibacterial activity was observed for the extracts of S. cumini and T. chebula on E. faecalis dentinal biofilm and its planktonic counterparts. The smear layer was efficiently removed by the seed extracts of T. chebula alone. Seed extracts of T. foenum neither possessed antibacterial effect nor smear layer removal ability. Conclusion: The extracts of T. chebula seeds may replace conventional irrigant due to its antibacterial properties and smear layer removing the ability. The extracts of S. cumini may be used as an intracanal medicament as it exhibited a bactericidal effect against the E. faecalis dentinal biofilm following 18 hours of incubation.


Subject(s)
Microscopy, Electron, Scanning/instrumentation , Root Canal Preparation/instrumentation , Syzygium/microbiology , Plant Preparations/therapeutic use , Endodontics , Statistics, Nonparametric , Biofilms , Agar , India/epidemiology , Anti-Bacterial Agents
8.
Braz. oral res. (Online) ; 34: e035, 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1100934

ABSTRACT

Abstract Although fiber-reinforced composites are commonly used in dental practice, whether fiber-reinforced crowns and fixed partial dentures can be used as definitive prostheses remains to be determined. This study used scanning electron microscopy to evaluate the load-bearing capacity of non-reinforced and fiber-reinforced composite (FRC) molar crowns prepared by computer-aided design/computer-aided manufacturing (CAD/CAM). The crowns were fabricated from three empirical FRC blocks, one empirical composite block, and one commercial ceramic block. The FRC resin was prepared by mixing BaO silicate particles, E-glass fiber, and dimethacrylate resin. Specimens were divided into five groups (n = 10), differing in the amounts of filler, resin, and fiber. Crowns were statically loaded until fracture. One-way analysis of variance and Tukey's post hoc multiple comparison tests were used for statistical analyses. The groups showed significant differences in load-bearing capacity; empirical bidirectional FRC resin blocks had the highest capacity, while commercial ceramic blocks had the lowest capacity. Molar crowns formed from FRC resin blocks had higher load-bearing capacity compared to non-reinforced composite resin and ceramic blocks. These results show that fiber reinforcement increased the load-bearing capacity of molar crowns.


Subject(s)
Humans , Weight-Bearing , Computer-Aided Design , Composite Resins/chemistry , Crowns , Reference Values , Surface Properties , Materials Testing , Microscopy, Electron, Scanning , Ceramics/chemistry , Reproducibility of Results , Dental Prosthesis Design , Evaluation Study , Molar
9.
Dent. press endod ; 9(2): 43-49, maio 2019. tab, Ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1024793

ABSTRACT

Objetivo: esse estudo avaliou o efeito de protocolos de irrigação final, associados ao uso de EDTA e QMix, na remoção de smear layer. Métodos: foram utilizados 40 dentes humanos com canal único. Os canais foram instrumentados com sistema ProTaper Universal SX-F3. As substâncias químicas utilizadas durante o preparo foram hipoclorito de sódio a 5,25% (NaOCl) ou clorexidina a 2% (CHX) gel. Terminado o preparo, os dentes foram divididos em oito grupos, de acordo com os irrigantes: G1) NaOCl 5,25% + EDTA 17% + NaOCl 5,25%; G2) NaOCl 5,25% + EDTA 17% + água destilada (AD); G3) NaOCl 5,25% + QMix + NaOCl 5,25%; G4) NaOCl 5,25% + QMix + AD; G5) CHX 2% gel + EDTA 17% + CHX 2% solução; G6) CHX 2% gel + EDTA 17% + AD; G7) CHX 2% gel + QMix + CHX 2% solução e G8) CHX 2% gel + QMix + AD. As amostras foram avaliadas por microscopia eletrônica de varredura ambiental, antes e após os protocolos de irrigação final. As imagens foram classificadas por escores, em relação à presença de smear layer, e os dados foram analisados pelos testes de Kruskal-Wallis e de Mann-Whitney. Resultados: o G1 mostrou os melhores resultados em relação à remoção de smear layer (p < 0,05). A CHX gel 2% mostrou menor formação de smear layer, quando comparada ao NaOCl, após o preparo biomecânico; e o NaOCl apresentou melhor limpeza como irrigante final (p < 0,05). Conclusões: o NaOCl como irrigante final, combinado ao EDTA, mostrou melhor capacidade de remoção da smear layer (AU).


Introduction: This study evaluated the effect of different final irrigation protocols using EDTA and QMix on smear layer removal. Methods: The root canals of 40 single-rooted human teeth were prepared with ProTaper Universal SX - F3. The substances used were 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine gel (chlorhexidine), 2% chlorhexidine solution and distilled water. The teeth were divided into 8 groups, according to the irrigant used: G1: 5.25% NaOCl + 17% EDTA + 5.25% NaOCl; G2: 5.25% NaOCl + 17% EDTA + distilled water; G3: 5.25% NaOCl + QMix + 5.25% NaOCl; G4: 5.25% NaOCl + QMix + DW; G5: 2% chlorhexidine gel + 17% EDTA + 2% chlorhexidine solution; G6: 2% chlorhexidine gel + 17% EDTA + distilled water; G7: 2% chlorhexidine gel + QMix + 2% chlorhexidine solution; and G8: 2% chlorhexidine gel + QMix + distilled water. Samples were evaluated under environmental scanning electron microscopy (ESEM) before and after irrigation. ESEM images were classified according to smear layer scores, and the Kruskal-Wallis and Mann-Whitney tests were used for statistical analyses. Results: Group 1 had the best results for smear layer removal (p<0.05). Smear layer formation was lower when 2% chlorhexidine gel was used after cleaning and shaping than when the irrigant was 5.25% NaOCl, and 5.25% NaOCl had the best cleaning ability as a final irrigant. Conclusion: 5.25% NaOCl combined with EDTA was the best final irrigant for smear layer removal (AU).


Subject(s)
Root Canal Irrigants , Sodium Hypochlorite , Microscopy, Electron, Scanning , Smear Layer
10.
An. bras. dermatol ; 94(3): 358-360, May-June 2019. graf
Article in English | LILACS | ID: biblio-1011120

ABSTRACT

Abstract: Dermatofibroma is a proliferation of spindle cells located in the dermis. We used scanning electron microscopy to examine two histologically confirmed lesions and observed preserved collagen bundles in the perilesional area. In the lesional area, the collagen was denser, without formation of bundles. Higher magnification showed collagen with mesh-like appearance similar to stretched tufts of cotton. Very high magnification evidenced the tufts of cotton and spindle cells measuring 2 to 12 microns.


Subject(s)
Humans , Female , Middle Aged , Skin Neoplasms/pathology , Histiocytoma, Benign Fibrous/pathology , Microscopy, Electron, Scanning , Dermis/pathology
11.
An. bras. dermatol ; 93(5): 740-742, Sept.-Oct. 2018. graf
Article in English | LILACS | ID: biblio-949950

ABSTRACT

Abstract: Light microscopy of granuloma annulare shows mucin deposition with lympho-histiocytic infiltrate. We describe the ultrastructural three-dimensional aspects of a typical case of granuloma with characteristic histopathological findings. At the ultrastructural level, affected collagen bundles and granular mucin deposition were observed. Round cells corresponding to lymphocytes were identified. Bigger oval cells, corresponding to isolated or palisading histiocytes were also found. The ultrastructural aspects overlap with light microscopy and contribute to its iconographic documentation.


Subject(s)
Humans , Microscopy, Electron, Scanning , Collagen/ultrastructure , Granuloma Annulare/pathology , Histiocytes/ultrastructure , Mucins/metabolism
12.
An. bras. dermatol ; 93(4): 582-584, July-Aug. 2018. graf
Article in English | LILACS | ID: biblio-949921

ABSTRACT

Abstract: Sclerodermus sp. is an aculeate insect (Hymenoptera: Bethylidae), measuring 2-4 mm in length. It is a parasitoid and needs termites as hosts to complete its life cycle. It is found in a wide variety of woods and may accidentally sting humans who come near affected wooden objects. A 50-year-old woman presented two episodes of intense pruritic lesions. Clinical diagnosis of insect bite was doubtful since there were no pets at home, lesions had not started during summer and the patient denied rural activities. During a night episode of itching, the patient examined her bed and found 8 insects likely to be responsible for the bites. Scanning electron microscopy revealed typical features of a female of the genus (wingless and with multiple stingers at the lower end of the abdomen).


Subject(s)
Humans , Animals , Female , Middle Aged , Pruritus/etiology , Ectoparasitic Infestations/complications , Hymenoptera/ultrastructure , Insect Bites and Stings/complications , Microscopy, Electron, Scanning , Ectoparasitic Infestations/parasitology , Insect Bites and Stings/parasitology
13.
Braz. oral res. (Online) ; 32: e25, 2018. tab, graf
Article in English | LILACS | ID: biblio-889489

ABSTRACT

Abstract The objective of this study was to evaluate the in vitro effects, including surface morphological characteristics and chemical elemental properties, of different mouthwash formulations on enamel and dental restorative materials, simulating up to 6 months of daily use. Human enamel samples, hydroxyapatite, composite resin, and ceramic surfaces were exposed to 3 different mouthwashes according to label directions — Listerine® Cool Mint®, Listerine® Total Care, and Listerine® Whitening — versus control (hydroalcohol solution) to simulate daily use for up to 6 months. The samples were analyzed using scanning electron microscopy (SEM), infrared spectrophotometry (µ-Fourier transform infrared microscopy), energy-dispersive X-ray (EDX) spectroscopy, and color analysis before and after exposure. No relevant changes were observed in the morphological characteristics of the surfaces using SEM techniques. The physical and chemical aspects of the enamel surfaces were evaluated using mid-infrared spectroscopy, and EDX fluorescence was used to evaluate the elemental aspects of each surface. There was no variation in the relative concentrations of calcium and phosphorus in enamel, silicon and barium in composite resin, and silicon and aluminum in the ceramic material before and after treatment. No relevant changes were detected in the biochemical and color properties of any specimen, except with Listerine® Whitening mouthwash, which demonstrated a whitening effect on enamel surfaces. Long-term exposure to low pH, alcohol-containing, and peroxide-containing mouthwash formulations caused no ultra-structural or chemical elemental changes in human enamel or dental restorative materials in vitro.


Subject(s)
Humans , Ceramics , Composite Resins , Dental Enamel/drug effects , Durapatite , Ethanol/chemistry , Ethanol/pharmacology , Mouthwashes/chemistry , Mouthwashes/pharmacology , Salicylates , Terpenes , Color , Colorimetry , Drug Combinations , Hydrogen Peroxide/chemistry , Immersion , Materials Testing , Microscopy, Electron, Scanning , Oils, Volatile/chemistry , Reference Values , Reproducibility of Results , Spectrometry, X-Ray Emission , Spectroscopy, Fourier Transform Infrared , Surface Properties/drug effects , Time Factors
14.
Rev. odontol. UNESP (Online) ; 46(6): 330-335, Nov.-Dec. 2017. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-902685

ABSTRACT

Introdução: A rugosidade de superfície é uma limitação que interfere nos desempenhos mecânico e estético do cimento de ionômero de vidro (CIV), sendo necessária a utilização de procedimentos para acabamento e polimento adequados às propriedades desse material. Objetivo: Avaliar o efeito de diferentes sistemas de acabamento e polimento na rugosidade, dureza e superfície de restaurações realizadas com dois tipos de CIV. Material e método: Foram utilizados 100 corpos de prova (CP), divididos em 10 grupos, de acordo com o tipo de CIV (convencional e modificado por resina) e o sistema de acabamento e polimento empregado [C-tira de poliéster (controle); PD-ponta diamantada; DA-discos abrasivos; PE-ponta Enhance; BM-broca multilaminada]. Após sete dias em água destilada, os CP foram avaliados em Microscópio Eletrônico de Varredura (MEV) e submetidos aos testes de rugosidade de superfície e microdureza Vickers. A análise estatística foi realizada com ANOVA dois fatores e pós-Teste de Tukey. Resultado: A análise por MEV indicou superfície mais lisa no grupo BM em ambos os tipos de CIV. Quanto à rugosidade, observou-se diferença estatisticamente significante (p<0,05) entre grupos do CIV convencional, mas não houve diferença entre os tipos de CIV. Com relação à dureza, o CIV convencional apresentou melhores resultados que o modificado por resina. No fator materiais de acabamento e polimento, não se verificou diferença estatisticamente significativa, independentemente do tipo de CIV. Conclusão: os grupos BM apresentaram melhores resultados ao MEV; o tipo de CIV não influenciou os valores de rugosidade; o tipo de polimento não influenciou a dureza.


Introduction: The roughness of glass ionomer cement (GIC) is a limitation that interferes with its mechanical and aesthetic performance, and it is necessary to use appropriate finishing and polishing procedures in restorations produced with this material. Objective: To evaluate the effect of different finishing and polishing systems on roughness, hardness and surface of restorations performed with two types of GIC. Material and method: 100 specimens were made and divided into 10 groups, according to the type of GIC (conventional and resin modified GIC) and the finishing and polishing system used (C (Control) - Mylar strip; PD - diamond burs; DA - abrasive disks; PE - Enhance system; BM - carbide burs). After 7 days in distilled water, the specimens were evaluated by Scanning Electron Microscopy (SEM) and submitted to surface roughness and Vickers microhardness tests. Statistical analysis was performed by two-way ANOVA and Tukey post-test. Result: SEM analysis demonstrated a smoother surface in BM group in both types of GIC. Regarding roughness, a statistically significant difference (p <0.05) was observed between some groups of conventional GIC, but there was no difference between GIC types. Regarding hardness, conventional GIC showed better results than resin-modified GIC; Concerning to finishing and polishing materials factor, there was no statistically significant difference, regardless of the type of GIC. Conclusion: BM groups presented better results on SEM; The type of GIC did not influence the roughness values; The type of polishing did not influence the hardness.


Subject(s)
Surface Properties , Microscopy, Electron, Scanning , Analysis of Variance , Dental Polishing , Glass Ionomer Cements , Hardness Tests
15.
An. bras. dermatol ; 92(4): 527-530, July-Aug. 2017. graf
Article in English | LILACS | ID: biblio-886999

ABSTRACT

Abstract: We report the ultrastructural findings in a case of a 72-year-old black woman with confluent yellowish papules in the cervical region. She had no comorbidities. Ophthalmological examination, electrocardiogram, and echocardiogram were normal. Hematoxylin-eosin staining of the affected skin showed strong alterations in the mid-dermis with irregular clumps of eosinophilic material and loss of the normal parallel arrangement of collagen bundles. Orcein staining revealed that the elastic fibers lost their normal linear configuration, showing clump fragmentation, sometimes forming square structures. Transmission electron microscopy showed aberrant elastic fibers with an irregular outline and heterogenic inner structures. We also observed small elastic fibers. Collagen fibers showed a normal structure with irregular distribution. Scanning electron microscopy revealed important disorganization of collagen fibers and small stone-like deposits measuring around 5 µm associated with bigger structures ranging from 10-16 µm. Higher magnification revealed that these small stone-like structures were sometimes polyhedral-shaped or squared.


Subject(s)
Humans , Female , Aged , Pseudoxanthoma Elasticum/pathology , Dermis/ultrastructure , Elastic Tissue/ultrastructure , Skin/pathology , Spine , Staining and Labeling , Microscopy, Electron, Scanning , Collagen/ultrastructure , Microscopy, Electron, Transmission
16.
Chinese Journal of Otorhinolaryngology Head and Neck Surgery ; (12): 57-60, 2017.
Article in Chinese | WPRIM | ID: wpr-808034

ABSTRACT

Objective@#Using scanning electron microscope to observe the ultrastructure of utricular maculae of mouse.@*Methods@#Ten young (6 to 8 weeks) and ten old (>12 months) mice were executed, and their utricles were harvested and the specimens were processed, using scanning electron microscope to observe the structures of the utricles from the surface of otoconia layer to the roots of hair cell cilia.@*Results@#Under the scanning electron microscope, several ultrastructures were observed, including otoconia layer, unstructured gelatinous extracellular matrix layer, honeycomb-like gelatinous extracellular matrix layer, inter-cilia otoconia and hair cell cilia associated with these structures. When compared with young mouse, the otoconia surface of aged mouse was smoother, the gelatinous extracellular matrix between the adjacent otoconias was thinner.@*Conclusions@#Using SEM, ultrastructures can be clearly observed from surface otoconia layer to the roots of hair cell cilia. By the analysis of the ultrastructure of utricular maculae, it is helpful for investigation of the pathological mechanisms of vestibular diseases, such as otolith diseases.

17.
Imaging Science in Dentistry ; : 129-133, 2017.
Article in English | WPRIM | ID: wpr-191865

ABSTRACT

Dentinogenesis imperfecta is a dominant autosomal hereditary disorder of dentin formation that affects the deciduous and permanent teeth. Its etiology is characterized by inadequate cell differentiation during odontogenesis. The clinical characteristics of dentinogenesis imperfecta are discolored teeth with a translucency that varies from gray to brown or amber. Radiographically, the teeth exhibit pulp obliteration, thin and short roots, bell-shaped crowns, and periapical bone rarefaction. The aim of this report was to present a case of dentinogenesis imperfecta type II that was followed up over a 17-year period. This report also presents scanning electron microscopy images of the enamel and dentin, showing that both were altered in the affected teeth. The disease characteristics and the treatments that were administered are reported in this study to guide dentists with respect to the need for early diagnosis and adequate follow-up to avoid major sequelae.


Subject(s)
Humans , Amber , Cell Differentiation , Crowns , Dental Enamel , Dentin , Dentinogenesis Imperfecta , Dentinogenesis , Dentists , Early Diagnosis , Follow-Up Studies , Microscopy, Electron, Scanning , Odontogenesis , Tooth
18.
Arq. gastroenterol ; 53(4): 278-284, Oct.-Dec. 2016. tab, graf
Article in English | LILACS | ID: lil-794602

ABSTRACT

ABSTRACT Background The inherent complications of cirrhosis include protein-calorie malnutrition and micronutrient deficiencies.Changes in taste are detrimental to the nutritional status, and the mechanism to explain these changes is not well documented in the cirrhotic patients. Objective To evaluate the taste buds of cirrhotic rats. Methods Fourteen male Wistar rats were evaluated. After 16 weeks, the liver was removed to histologically diagnose cirrhosis, and blood was collected to perform liver integrity tests. The tongue was removed for histological examination and immunohistochemistry using antibodies against protein gene product PGP 9.5 and the sweet taste receptors T1R2 and T1R3. Morphological changes were determined by scanning electron microscopy. Serum zinc levels were measured. Results The cirrhotic animals, but not the control animals, exhibited zinc deficiency. In both groups, there was positive immunoreactivity for type II and III cells and T1R2 receptors. The cirrhotic animals had no immunoreactivity for T1R3 receptors. Scanning electron microscopy analysis of the cirrhotic group revealed a uniform tapering of the gustatory papillae. Conclusion In conclusion the experimental cirrhosis model mimicked the biochemical and histological parameters of human cirrhosis, therefore enabling a study of the gustatory papillae and taste buds.


RESUMO Contexto As complicações inerentes de cirrose incluem a desnutrição proteico-calórica e deficiências de micronutrientes. Alterações no paladar são prejudiciais para o estado nutricional e o mecanismo para explicar essas mudanças não é bem documentada nos pacientes cirróticos. Objetivo Avaliar as papilas gustativas de ratos cirróticos. Métodos Foram avaliados 14 ratos Wistar machos. Após 16 semanas, o fígado foi removido para diagnosticar histologicamente cirrose, e o sangue foi colhido para efetuar testes de integridade hepática. A língua foi removida para exame histológico e imuno-histoquímica utilizando anticorpos contra o gene da proteína PGP 9.5 e os receptores de sabor doce T1R2 e T1R3. As alterações morfológicas foram determinadas por microscopia eletrônica de varredura e os níveis de zinco no soro foram medidos. Resultados Os animais cirróticos, em relação aos animais controle, apresentaram deficiência de zinco significativa. Em ambos os grupos, houve imunorreatividade positiva para o tipo II e células III e receptores T1R2. Os animais cirróticos não tinham imunoreactividade para receptores T1R3. Microscopia eletrônica de varredura do grupo cirrótico revelou um afilamento uniforme das papilas gustativas. Conclusão O modelo de cirrose experimental imitou os parâmetros bioquímicos e histológicos de cirrose humana, portanto, permitindo um estudo das papilas gustativas e paladar.


Subject(s)
Humans , Animals , Male , Rats , Taste Buds/pathology , Tongue/pathology , Liver Cirrhosis, Experimental/chemically induced , Taste Buds/physiopathology , Tongue/physiopathology , Zinc/deficiency , Immunohistochemistry , Rats, Wistar
19.
An. bras. dermatol ; 91(5,supl.1): 125-127, Sept.-Oct. 2016. graf
Article in English | LILACS | ID: biblio-837936

ABSTRACT

Abstract Giant axonal neuropathy is a rare autosomal recessive neurodegenerative disease. The condition is characterized by neurons with abnormally large axons due to intracellular filament accumulation. The swollen axons affect both the peripheral and central nervous system. A 6-year old female patient had been referred to a geneticist reporting problems with walking and hypotonia. At the age of 10, she became wheelchair dependent. Scanning electron microscopy of a curly hair classified it as pili canaliculi. GAN gene sequencing demonstrated mutation c.1456G>A (p.GLU486LYS). At the age of 12, the patient died due to respiratory complications. Dermatologists should be aware of this entity since hair changes are considered suggestive of GAN.


Subject(s)
Humans , Female , Child , Giant Axonal Neuropathy/pathology , Hair Diseases/pathology , Microscopy, Electron, Scanning , Fatal Outcome , Giant Axonal Neuropathy/complications , Hair/pathology , Hair Diseases/genetics , Mutation
20.
Biomédica (Bogotá) ; 36(3): 354-358, jul.-set. 2016. ilus, tab
Article in Spanish | LILACS | ID: biblio-828012

ABSTRACT

Introducción. Se han propuesto clasificaciones de las extensiones cuticulares de los insectos para utilizarlas como herramienta taxonómica. A pesar de los diversos estudios morfológicos adelantados en triatominos, el conocimiento que se tiene sobre la distribución y los tipos morfológicos de estas estructuras en la subfamilia aún es escaso y fragmentario. Objetivo. Describir las setas de diferentes regiones de la cutícula externa de varias especies de triatominos mediante microscopía electrónica de barrido. Materiales y métodos. Se lavaron y se secaron especímenes de Eratyrus mucronatus, Triatoma maculata, Panstrongylus geniculatus y Belminus ferroae, y a continuación se disecaron diferentes regiones de sus cuerpos y se montaron sobre cinta adhesiva de grafito de doble faz en soportes metálicos. Se metalizaron con oro y se tomaron las micrografías para su posterior análisis. Resultados. Se describieron nueve tipos de setas cuticulares. En B. ferroae y T. maculata se encontraron cinco tipos de setas, en P. geniculatus, cuatro, y en E. mucronatus, un solo tipo. Según la tipología propuesta, la seta de tipo 3 fue la más común en cada especie, excepto en B. ferroae, en la cual predominó la seta de tipo 1a. Conclusión. La seta más común en las especies de la tribu Triatomini (T. maculata, E. mucronatus y P. geniculatus) fue la de tipo 3; la seta de tipo 1a fue específica para la especie B. ferroae, taxón de la tribu Bolboderini, lo cual permite suponer que la morfología superficial de las setas podría tener valor taxonómico a nivel de tribu.


Introduction: The classification of the cuticular extensions of insects has been proposed as a taxonomic tool; however, the internal and external processes of the cuticular extensions of the Triatominae subfamily have not been fully analyzed and categorized. Objective: To describe the setae from different regions of the outer cuticle of several triatomine species by scanning electron microscopy. Materials and methods: Triatomines were washed and dried, after which different regions of the body from Eratyrus mucronatus, Triatoma maculata, Panstrongylus geniculatus and Belminus ferroae specimens were dissected, mounted on graphite double-sided adhesive tape over metal supports, metalized with gold and micrographed for further analysis. Results: We described nine types of cuticular setae. We found five types of setae in B. ferroae and T. maculata, four in P. geniculatus and only one in E. mucronatus. According to the proposed typology, type 3 seta was the most common in T. maculata, P. geniculatus and E. mucronatus, whereas type 1a predominated in B. ferroae. Conclusion: Type 3 seta was the most common in the Triatomini tribe (T. maculata, E mucronatus and P. geniculatus), whereas type 1a seta was specific to B. ferroae (tribe Bolboderini), suggesting that the surface morphology of the setae may have taxonomic value at tribe taxonomic level.


Subject(s)
Triatominae , Microscopy, Electron, Scanning , Sensilla
SELECTION OF CITATIONS
SEARCH DETAIL